Simulation & Analysis
Short-Circuit
ANSI / IEEE & IEC
Standards
Transient fault analysis
(IEC 61363)
Integrates with
protective device
coordination
Automatic device
evaluation
Load Flow
Power flow
Demand load
Voltage drop
Automatic temp.
correction
PF correction
Multiple loading &
generation categories
Automatic device
evaluation
Real & reactive power
losses
Arc Flash
IEEE 1584-2002 Standard
Embedded short circuit
calculation
Embedded device
coordination
NFPA 70E-2000 & 2004
methods
Cubic box & open air
Report & label
generation
Motor
Acceleration
Dynamic motor
acceleration
Voltage flicker
Motor dynamic models
Static motor starting
Multi-sequence starting
Conventional & soft
starting devices
Load transitioning
MOV simulation
Harmonics
Harmonic load flow
Frequency scan
IEEE 519 Standard
Filter design & sizing
Automatic distortion
limit evaluation
(THD & IHD)
Telephone influence
factors (TIF & I*T)
Automatic alerts of
violations
Coordination/Selectivity
Star (Device
Coordination)
Sequence-of-operation
Graphically adjustable
device settings
Graphical display of all
possible settings
Extensive device library
(verified & validated)
Embedded short circuit
analysis
Embedded motor
acceleration analysis
Integrated with one-line
diagram
Multi-axis time current
curves
Comprehensive TCC
options
Adjustable
magnifying-glass zoom
view
Drag or calculate time
differences
Multi-function/level
relays
Built-in ARTTS hardware
interface
Display of actual
transient response
ARTTS (Advanced
Relay Testing
& Transient Simulator)
Test, simulate, &
calibrate
Relays, meters, &
transducers
Powerful & lightweight
High accuracy
Self-calibrating
Multiple current &
voltage outputs
Auxiliary DC supply
Ground Grid Systems
IEEE 80 & 665 methods
Finite element method
Conductor & rod
optimization
3-D plots for step,
touch, & absolute
potentials
3-D irregular
configurations |
|
Distribution Systems
Unbalanced Load Flow
Per phase power flow
Phase & sequence voltage
& current
3-Phase (3W & 4W),
2-Phase (2W & 3W)
& 1-Phase
Demand load & voltage
drop
Unbalanced loads & line
impedance
Transmission line
coupling
Power factor correction
Automatic device
evaluation (alerts)
Automatic temperature
correction
Real & reactive power
losses
Optimal Power
Flow
Active & reactive power
optimization
Generation & utility
cost minimization
Shunt Mvar & series
compensation
Minimize control
movements
Voltage & line flow
security index
Bus voltage & branch
flow constraints
Consider fuel & energy
costs
Optimal
Capacitor Placement
Optimal location & bank
size
Minimize installation &
operation costs
Individual source or
average energy cost
Voltage and/or power
factor objectives
Minimum, maximum, &
average loading
Branch capacity release
& cost savings
Review capacitor impact
on the system
Capacitor control method
Reliability
Assessment
Load point/bus
reliability indices
System reliability
indices
Reliability cost/worth
indices
Sensitivity analyses
Fault isolation
Load restoration
Single & double
contingencies
Transmission
Line
Overhead line parameters
& coupling
Sag & tension vs.
temperature
Conductor ampacity vs.
temperature
Physical configuration
to impedance calculator
Multiple spans between
dead-end structures
Level spans of unequal
length
Inc.des effects of wind,
temperature, & k factor
High Voltage DC
Systems
Detailed converter
modeling
Composite AC/DC
inverter/AC systems
Combined transformer
model
Automatic harmonic
spectrum calculation
Built-in control schemes
Easy-to-use dynamic
modes
Transformer Tap
Optimization
ANSI/IEEE C57.116
Standard
Optimize unit
transformer turns ratio
Considers system voltage
variation
Considers generation
station auxiliary load
Generator reactive
capacity vs. voltage
plots
GIS Map
Display unlimited GIS
presentations
(maps) in ETAP
Display analysis results
on GIS Map
Synchronize GIS data to
ETAP projects
Database mapping via a
graphic user interface
Add, modify, or delete
elements for data
synchronization
View modifications &
accept/reject actions
Use map tools – zoom
in/out/extent, pan, etc.
Map attributes of GIS to
ETAP elements
Consistency checks
during data
synchronization
|
|
Dynamics & Transients
Transient Stability
Simulate any disturbance
& practical action
Unlimited events &
actions
Automatic relay action
(27, 32, 50, 59, 67, 81)
Automatic load shedding
Short & long time
simulation
Variable simulation time
Multi-subsystems with
multi-reference machines
Comprehensive exciter,
governor, & PSS models
Shaft torsion &
multi-mass modeling
Generator
Start-Up
Start generators from a
cold state (black start)
Accelerate motors &
connected loads
Utilize any desired
frequency & voltage
Determine optimal
loading time
Schedule of load
sequence
Analysis of generator
starting behavior
Frequency dependent
machine &
network models
User-Defined
Dynamic Models
Governors, exciters, &
power system
stabilizers (PSS)
Create custom control
block diagrams
Library of control
blocks & elementary
functions
Step response test for
each model
Run-time compile within
transient stability
Import/compile models
built in Simulink®
Parameter
Estimation
Induction machine
equivalent circuits
Single-cage models
Optional deep-bar
effects
Cable Systems
Underground Raceway
Systems
Neher-McGrath method
IEC 287 method
Steady-state temperature
Transient temperature
Ampacity optimization
Automatic cable sizing
Cable Pulling
3-D isometric view
Pull multiple cables
Forward & reverse
tension
Sidewall pressure
Pull different size
cables
Vertical & horizontal
levels
Checks for NEC
requirements
Cable Ampacity
Duct banks
Direct buried
Trays
Conduit in air
Air drops
ICEA & NEC methods
Cable Sizing
Optimal & alternative
sizes
Ampacity & voltage drop
options
Size based on any
one-line element
Control System Diagram
Drag &
drop control relays,
solenoid, cables, etc.
Control logic simulation
(contacts,
pushbuttons, etc.)
Voltage drop calculation
including inrush
currents
Automatic alert for
pickup & dropout
voltages
Automatic overloading
alerts
Fully integrates with
one-line diagram
Comprehensive device
library (verified &
validated) |
|
Real-Time Systems
Power System Monitoring
& Simulation (PSMS)
Advanced Monitoring
Real-Time Simulation
Event Playback /
Historian
Trending / Alarm /
Energy Cost Analysis
Energy
Management System (EMS)
Intelligent energy
management
Demand-side management
Automatic generation
control
System optimization
System automation
Intelligent Load
Shedding (ILS)
Optimal load
preservation
Fast response time
Reliable operation
Minimum load shedding
Data Exchange
DataX
Convert third party
databases
Turnkey database
synchronization
Customizable
one-way/two-way data
channels
Automatic one-line
diagram generation
Data range checking
Data validation &
consistency checking
Library data
substitution
e-DPP® Interface
Map attributes of e-DPP
to ETAP elements
Synchronize e-DPP data
to ETAP projects
Database mapping via
graphic user interface
SmartPlant®
Electrical Interface
Map attributes of SPEL
to ETAP elements
Synchronize SPEL data to
ETAP projects
Database mapping via
graphic user interface
DC Systems
Load Flow
Integrated AC & DC
systems
Voltage drop
Power losses
IEEE 946 Standard
Battery auto-activation
Short-Circuit
Integrated AC & DC
systems
IEEE 946 Standard
Calculate total fault
current
Calculate current rising
time
Battery Sizing &
Discharge
Verify battery
capability
Calculate battery duty
cycle
Detailed battery library
Multiple diversity &
correction factors
Discharge via DC load
flow
or duty cycle summation
IEEE 308, 485, & 946
Standards
Panel Systems
Intelligent panel design
& analysis
1-Phase (2W & 3W)
3-Phase (3W & 4W)
ANSI & IEC Standards
NEC load factors
Load flow with graphical
per phase display
Automatic updating of
upstream panels
Customizable Excel® &
Crystal Reports®
Panel schedule with
internal & external
feeders |
|